What was found
C2 CHECK - RT FUEL PANEL AND CUTOUT 626AT HAS FRETTING AND ARCING. BLENDED PANEL 624AT IAW RD 8/4-57-442. REMOVED CORROSION FROM WING MATING SURFACE IAW RD 8/4-57-445. MINIMUM REMAINING THICKNESS .078" REF NTM 51-00-02-250-801. CONFIRMED AFFECTED AREA IS CRACK FREE REF NTM 51-00-01-250-801. MATERIAL LOSS FOUND TO BE WITHIN LIMITS ON MATING SURFACE IAW RD 8/4-57-445. REMOVED CORROSION FROM PANEL, REMAINING MATERIAL THICKNESS .109" WITHIN LIMITS IAW RD 8/4-57-442. CONFIRMED PANEL AFFECTED AREA IS CRACK FREE REF NTM 51-00-01-250-801. APPLIED ALODINE AND PRIMER TO WING MATING SURFACE IAW RD 8/4-57-445. APPLIED ALODINE AND PRIMER TO PANEL 624AT IAW RD 8/4-57-442. INSTALLED SEALS AND COMPLETED PANEL REPAIR REF RD 8/4-57-442.