What was found
C2 CHECK - RT WING FUEL PANEL AND CUTOUT 624FT HAS FRETTING AND ARCING. REMOVED CORROSION FROM FUEL PANEL MATING SURFACE IAW RD 8/4-57-445. MINIMUM REMAINING THICKNESS .088" REF NTM 51-00-02-250-801. CONFIRMED AFFECTED AREA IS CRACK FREE REF NTM 51-00-01-250-801. MATERIAL LOSS ON MATING SURFACE FOUND TO BE WITHIN LIMITS IAW RD 8/4-57-445. REMOVED CORROSION, LEAVING A REMAINING MATERIAL THICKNESS .117", WITHIN ALLOWABLE LIMITS IAW RD 8/4-57-442. CONFIRMED PANEL IS CRACK FREE REF NTM 51-00-01-250-801. APPLIED ALODINE AND PRIMER TO WING MATING SURFACE IAW RD 8/4-57-445. APPLIED ALODINE AND PRIMER TO PANEL 624FT IAW RD 8/4-57-442. APPLIED SEALS TO PANEL AND COMPLETED PANEL REPAIR REF RD 8/4-57-442.