What was found
C5 CHECK - FR 1.000 LWR FLANGES ARE CORRODED FROM STR 32L TO 31R. REMOVED CORROSION IAW SRM 51-21-00. MIN REMAINING THICKNESS .045" NTM 51-00-02-250-801. MATERIAL LOSS AT FLANGE AT STA 1.00, STR 33-32R FOUND TO BE OUT OF LIMITS AND FLANGES AT STA 1.00 STR 33-32L AND STR 32R-31R WERE FOUND WITHIN LIMITS IAW RD 8/4-53-2344. REMOVED FRAME, FLANGE IAW SRM 53-10-15-02-01 AND RD 8/4-53-017 FOUND CORROSION ON INTERNAL SURFACE OF FUSELAGE SKIN COMMON TO FRAME FLANGE. REMOVED CORROSION FROM SKIN IAW SRM 51-21-00-00-02. MEASURED REMAINING THICKNESS .059" REF NTM 51-00-02-250-801. CONFIRMED CRACK FREE CONDITION OF SKIN IN AFFECTED AREA REF NTM 51-00-01-250-801. REMAINING THICKNESS ON FUSELAGE SKIN IS WITHIN LIMITS IAW SRM 53-20-31-02-01. APPLIED ALODINE AND PRIMER IAW SRM 51-21-10 AND 51-25-10. FABRICATED FRAME FLANGE IAW RD 8/4-53-017, CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-01-250-801. INSTALLED REPAIR FLANGE, TREATED AND PRIMED AREA AS REQUIRED AND COMPLETED REPAIR IAW RD 8/4-53-017 AND RD 8/4-53-2344.