As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
C5 CHECK - FR 32.400 LOWER FLANGE BETWEEN STR 32R AND 31R IS CORRODED. REMOVED CORROSION FROM FLANGE IAW SRM 51-21-00. MIN REMAINING THICKNESS .034" REF NTM 51-00-02-250-801. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW SRM 53-20-15. FRAME SECTION TO BE REPLACED ON NR 100037, WO 100785.