As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
C5 CHECK - SKIN LAP INBD OF STR 31L HAS 2 AREAS OF CORROSION BETWEEN FR341.000 AND 361.000. REMOVED CORROSION IAW SRM 51-21-00. CONFIRMED CRACK FREE CONDITION REF 51-00-01-250-801. MIN THICKNESS REMAINING .048" MAX .050" REF NTM 51-00-02-250-801. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-505. APPLIED ALODINE, PRIMER AND PAINT IAW SRM 51-21-10, 51-25-10 AND 51-25-15-02-01.