C5 CHECK - AFT SIDE OF FRAME AT STA 18.250 IS CORRODED AT STR SPLICE ATTACH POINT STR 31R. R & R FRAME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C5 CHECK - AFT SIDE OF FRAME AT STA 18.250 IS CORRODED AT STR SPLICE ATTACH POINT STR 31R. R & R FRAME.