What was found
C4 CHECK - INTERNAL FUSELAGE UNDERFLOOR AT STA 32.4000 FRAME FLANGES HAVE CORROSION BETWEEN STR 33 TO 32R, 32R TO 30R. REMOVED CORROSION IAW RD 8/4-53-2344. MIN MATERIAL REMAINING .039" REF NTM 51-00-02-250-801, FLANGES ARE WITHIN LIMITS IAW RD 8/4-53-2344. CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-01-250-801. TREATED, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-25-02-01 AND 51-25-05-02-01.