What was found
C2 CHECK - FLOOR SUPPORT WEB AT STA X32.400 JUST AFT OF FWD PAX DOOR ENTRY HAS AREAS OF CORROSION. REMOVED FLOOR SUPPORT WEB TO FOM IAW SRM 51-42-45. FOUND TO BE OUT OF LIMITS IAW SRM 51-14-00. FABRICATED FLOOR SUPPORT WEB IAW TC 6-53-967 USING .050 2024T3. INSTALLED FLOOR SUPPORT WEB IAW SRM 51-42-45.