As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PDX A7 CHECK. CORROSION FOUND AT THE LOWER AFT CORNER OF THE LAVATORY SERVICE DOOR OPENING. DRILLED OUT RIVETS AND CUT OUT DAMAGE AREA IAW RD 8/4-53-347. PERFORMED HFEC OF REMAINING MATERIAL FOR CRACKS. NO CRACKS NOTED. FABRICATED REPAIR PACKERS AND BACKING PLATE. DRILLED, DEBURRED, ALODINED, PRIMED AND PAINTED WHITE. INSTALLED PACKERS AND BACKING PLATE IAW RD.