C6 CHECK - DURING INSP FOUND CORROSION ON FS 280 BUTTSTRAP BETWEEN STR 25L AND 26R. CORROSION FOUND TO BE LOCATED IN NO DAMAGE ALLOWED AREA IAW SRM 53-21-01-101-002-A01. SENT ENGINEERING REQUEST. PERFORMED FPI ON AREA IAW NDTM 51-20-008-230-A01. TREATED, PRIMED AND PAINTED AREA IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01 AND 51-25-16-001-001-A01. ALL WORK PERFORMED COMPLIES WITH QX TASK CARD REO 670-53-21-652.