As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
C6 CHECK - CORROSION FOUND ON FREE FLANGE OF STR 26R BETWEEN FS 280.00 - 295.00. BLENDED CORROSION, DAMAGE IN NO DAMAGE ALLOWED AREA IAW SRM 53-21-03-991-855. ALL BLENDS DONE IAW SRM 51-21-06-001-001-A01. PERFORMED FPI ON BLENDED AREAS IAW NDTM 51-20-08, NO EVIDENCE OF CRACKS FOUND. R & R STRINGER SECTION IAW REO 670-53-21-643.