What was found
RFD - C6 CHECK - CORROSION FOUND ON STR 26L AT FS 300. BLENDED CORROSION IAW SRM 51-21-06-001-001-A01. BLENDS WITHIN LIMITS IAW SRM 53-21-03-101-002-A01. PERFORMED FPI ON BLENDED AREAS IAW NDTM 51-20-08, NO EVIDENCE OF CRACKS FOUND. TREATED, PRIMED AND PAINTED AS REQUIRED IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01 AND 51-25-16-001-001-A01. APPLIED CORROSION PREVENTATIVE COMPOUND IAW SRM 51-21-11-001-001-A01.