What was found
C6 CHECK - DURING INSP, FOUND CORROSION ON NLG JACK FITTING SUPPORT ANGLE ATTACH FLANGE. BLENDED SURFACE CORROSION IAW SRM 51-21-06-001-001-A01. DEEPEST BLEND ON FLANGES IS .003 MATERIAL REMOVED. ORIGINAL THICKNESS IS .063. PERFORMED FPI ON BLENDED AREAS OF NLG IAW NDTM 51-20-08, NO EVIDENCE OF CRACKS FOUND. SENT ENGINEERING REQUEST. RECEIVED REO 670-53-11-573. BLENDED AREA ACCEPTABLE IAW REO. TREATED, PRIMED AND PAINTED IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01 AND 51-25-16-001-001-A01. APPLIED CORROSION INHIBITING COMPOUND IAW SRM 51-21-11-001-001-A01. ALL WORK DONE IAW TASK CARD REO 670-53-11-573.