What was found
C6 CHECK - DURING INSP, FOUND CORROSION ON STR 25L AT FS 280, FS 310. REMOVED ALL CORROSION AND FOUND FS 280-FS 295 TO BE IN NO DAMAGE ALLOWED AREA. PERFORMED FPI IAW NDTM 51-20-08, NO EVIDENCE OF CRACK FOUND. FABRICATED REPAIR PARTS IAW REO 670-53-21-643. TREATED, PRIMED AND PAINTED IAW SRM 51-21-11-001-001-A01, 51-25-06-001-001-A01, 51-25-16-001-001-A01 AND REO 670-53-21-643. INSTALLED REPAIR IAW REO 670-53-21-643. ALL WORK DONE IAW TASK CARD REO 670-53-21-643.