What was found
C6 CHECK - DURING INSP FOUND CORROSION ON STR 25R AT FS295-310. BEGAN CORROSION REMOVAL, FOUND STR TO BE OUT OF LIMITS IAW SRM 53-21-03-101-002-A01. MADE REPAIR IAW REO 670-53-21-643.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C6 CHECK - DURING INSP FOUND CORROSION ON STR 25R AT FS295-310. BEGAN CORROSION REMOVAL, FOUND STR TO BE OUT OF LIMITS IAW SRM 53-21-03-101-002-A01. MADE REPAIR IAW REO 670-53-21-643.