Service difficulty report · Monitor · Bombdr DHC8402

Difficulty date
March 3, 2011
Submitted
March 7, 2011
Operation
Air carrier
Aircraft
N407QX
Make and model
Bombdr DHC8402
Aircraft serial
4049
Aircraft time
23,705 hours, 24,852 cycles
Part
Monitor
Part number
4100S01806
Part serial
0115
Condition
Malfunctioned
Location
Zone 200
Part time
16,934 hours, 8,119 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CLIMBOUT DEICE PRESS CAUTION LIGHT ILLUMINATED. DEICE PRESSURE WAS NORMAL BUT BOOT SET NR 6 REMAINED ILLUMINATED. RETURNED TO FIELD, LANDING UNEVENTFUL. CDS ANTI ICE SHOWED NO FAULTS. NVM FULL, CLEARED NVM. GROUND RAN ACFT VERIFIED DISCREPANCY. C/W TACTILE & VISUAL INSP OF AFFECTED BOOTS. CDS SHOWED LOW PRESS 4A, 5A, 6A FAIL. R & R NR 6 DDV, NO HELP REINSTALLED ORIGINAL VALVE, REF AMM 30-11-16-000-801 & 30-11-16-400-801. R & R TMU IAW AMM 30-11-01-000-801 & 30-11-01-400-801. AIRFRAME DEICE FUNCTION CHECKS GOOD, REF AMM 30-11-00-720-801. NO CDS FAULTS NOTED. RETURNED TO SERVICE.