What was found
SLIGHT BURNING ODOR NOTICED DURING POWER REDUCTION AT ALTITUDE. COMPLIED WITH FIM TASK 71-00-00-810-817 AND SL DH8-400-SL-012A. OPERATED BLEED AIR IAW AMM 36-11-00-710-802 FOR 30 MINS. NO ODOR NOTED. REPLACED ENGINE DRIVEN HYD PUMP FOUND TO BE LEAKING. RETURNED TO SERVICE.