What was found
C2 - LT WING FUEL TANK ACCESS PANEL 524FT MATING SURFACE HAS FRETTING. REMOVED AND BLENDED DAMAGE IAW RD 8/4-57-442. PANEL IS WITHIN TOLERANCE FOR REWORK IAW RD 8/4-57-442. TREATED AND PRIMED IAW RD 8/4-57-442.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C2 - LT WING FUEL TANK ACCESS PANEL 524FT MATING SURFACE HAS FRETTING. REMOVED AND BLENDED DAMAGE IAW RD 8/4-57-442. PANEL IS WITHIN TOLERANCE FOR REWORK IAW RD 8/4-57-442. TREATED AND PRIMED IAW RD 8/4-57-442.