What was found
FRAME X19.400 LOWER FLANGE HAS CORROSION BETWEEN STRINGER 28S AND 29S. REMOVED CORROSION FROM AFFECTED AREAS IAW SRM 51-21-00-00-02. FOUND TO BE WITHIN LIMITS OF RD 8/4-53-2344. ALODINED, PRIMED, PAINTED IAW RD 8/4-53-2344.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME X19.400 LOWER FLANGE HAS CORROSION BETWEEN STRINGER 28S AND 29S. REMOVED CORROSION FROM AFFECTED AREAS IAW SRM 51-21-00-00-02. FOUND TO BE WITHIN LIMITS OF RD 8/4-53-2344. ALODINED, PRIMED, PAINTED IAW RD 8/4-53-2344.