What was found
FRAME X49.500 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 30P AND 32P. REMOVED CORROSION IAW SRM 51-21-00-00-01. FOUND FLANGES TO BE WITHIN LIMITS PER RD 8/4-53-2344. TREATED,PRIMED AND PAINTED PER RD 8/4-53-2344.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME X49.500 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 30P AND 32P. REMOVED CORROSION IAW SRM 51-21-00-00-01. FOUND FLANGES TO BE WITHIN LIMITS PER RD 8/4-53-2344. TREATED,PRIMED AND PAINTED PER RD 8/4-53-2344.