What was found
FRAME X71.200 LOWER FLANGE HAVE CORROSION BETWEEN STRINGER 29S & 32S. BLENDED CORROSION IAW RD 8/4-53-2344. HFEC CONFIRMED CRACK FREE REF NTM, 51-00-02-250-801 UT REMAINING THICKNESS MEASURED .040" IN REF NTM 51-00-01-250-801. FOUND TO BE WITHIN LIMITS OF RD 8/4-53-2344. ALODINE, PRIMED AND PAINTED IAW RD 8/4-53-2344.