As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME X156.000 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 30S AND 32S. BLENDED CORROSION IAW RD 8/4-53-2344. REMAINING THICKNESS IS .046". CONFIRMED CRACK FREE REF NTM 51-00-02-250-801 AND 51-00-01-250-801. BLEND IS WITHIN LIMITS OF RD 8/4-53-2344. ALODINED, PRIMED, PAINTED AND APPLIED CPC IAW RD 8/4-53-2344.