What was found
FRAME X49.500 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 30S AND 32S. REMOVED CORROSION IAW SRM 51-21-00-00-01. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. TREATED,PRIMED AND PAINTED IAW RD 8/4-53-2344
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME X49.500 LOWER FLANGES HAVE CORROSION BETWEEN STRINGERS 30S AND 32S. REMOVED CORROSION IAW SRM 51-21-00-00-01. FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. TREATED,PRIMED AND PAINTED IAW RD 8/4-53-2344