What was found
STRINGER 24S HAS CORROSION JUST FWD OF STA X116.000. REMOVED CORROSION IAW SRM 51-21-00-00-01. MINIMUM REMAINING THICKNESS .048" FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-3812. TREATED, PRIMED,PAINTED AND APPLIED CPC IAW RD 8/4-53-3812.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 24S HAS CORROSION JUST FWD OF STA X116.000. REMOVED CORROSION IAW SRM 51-21-00-00-01. MINIMUM REMAINING THICKNESS .048" FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-3812. TREATED, PRIMED,PAINTED AND APPLIED CPC IAW RD 8/4-53-3812.