What was found
FRAME X19.400 LOWER FLANGES HAVE CORROSION BETWEEN STRINGER 30S AND 32S. REMOVED CORROSION FROM AFFECTED AREA IAW SRM 51-21-00-00-02 AND RD 8/4-53-2344. MINIMUM REMAINING THICKNESS .037" FOUND TO BE IN LIMITS OF RD 8/4-53-2344. TREATED, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-45-02-01 AND 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-01-390-801.