What was found
AFT SERVICE DOOR SILL PLATE CORRODED. CORROSION REMOVED IAW 51-21-00-00-02. SENT ENGINEERING REQUEST. AREA OUT OF LIMITS IAW SDR 53-40-21-00-01. LOCATED HOLES AND ROUGH CUT NEW SEAL PLATE IAW SRM 51-24-35-02-01. FABRICATED NEW SILL IAW EC 6-53-999. TREATED WITH ALUMINUM PREP AND ALODINE IAW 51-21-10-02-01. PRIMED FABRICATED SILL IAW SRM 51-25-10-02-01. INSTALLED SILL PLATE AND SLICE PLATES IAW SRM 51-40-05, 51-40-07, 51-40-15, 51-42-15 AND 51-42-05. APPLIED CIC TO WORKED AREA IAW SRM 51-21-00-00-01.