What was found
CORROSION FOUND AT FS 32.400, Z100.032 WEB AT AFT SIDE OF FWD PASSENGER DOOR FLOOR LEVEL Y EQUALS 27L TO 38L. REMOVED ANGLE .013" MATERIAL REMOVED IAW SRM 51-21-00-00-02 AND 51-42-05-00-01. FABRICATED NEW ANGLE FROM 2024-T3 .050 IAW DWG 824844, SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED FABRICATED SUPPORT ANGLE IAW SRM 51-42-05 AND TC 6-53-1000, APPLIED PRIMER AND CIC IAW TC 6-53-1000. ALL WORK DONE IN CONFORMITY WITH TC 6-53-1000.