As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PAX DOOR BOTTOM STEP REINFORCEMENT PLATE FOUND CORRODED. BLENDED CORROSION IAW SRM 51-21-00-00-02. FOUND TO BE OUT OF LIMITS IAW SRM 51-21-00-00-02. FABRICATED REPLACEMENT LOWER STEP IAW DWG NR 85217076, AND SRM 51-40-07-02-01. TREATED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED INSTALLED STEP PLATES IAW SRM 51-41-05-00-01 AND AMM 25-25-01-400-801.