What was found
FLOOR WEB ON SEAT TRACK 5 IS CORRODED STA 1.00 TO 19.000. REMOVED CORROSION FROM WEB IAW SRM 51-21-00-00-01. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW SRM 53-20-43-00-01. REMOVED WEB IAW SRM 51-42-05-02-01. FABRICATED NEW WEB IAW SRM 51-24-35-02-01 AND 51-40-07-02-01. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED WEB IAW SRM 51-42-05-02-01 AND TOPCOATED IAW SRM 51-25-15-02-01.