As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBOARD ANGLE BY AFT PAX DOOR AFT END IS CORRODED FORWARD OF STA X697. REMOVED CORROSION IAW SRM 51-21-00-00-02. MINIMUM REMAINING THICKNESS .040". CONFIRMED CRACK FREE REF NTM 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-3892. RESTORED SURFACE PROTECTION IAW RD 8/4-53-3892. COMPLIED WITH HORIZON TASK CARD RD 8/4-53-3892.