FRAME X28.000 LOWER FLANGE HAS CORROSION ABOVE STRINGER 25P JUST BELOW FWD LT PAX DOOR THRESHOLD. REMOVED CORROSION FROM FLANGE ANGLE IAW SRM 51-21-00-00-01. FOUND TO BE OUT OF TOLERANCE IAW SRM 53-20-23-00-01. FABRICATED NEW FLANGE FROM 7075 T6 .050 IAW TASK CARD 6-53-1006. INSTALLED FLANGE IAW SRM 51-42-5-02-01.