What was found
FOUND CORROSION ON RT AFT SERVICE DOOR SILL PLATE. BLENDED CORROSION IAW SRM 51-21-00-02. BLENDED AREA IS A NO REPAIR ALLOWED AREA. ENGINEERING REQUEST SENT TO MFG. FABRICATED AFT SERVICE DOOR EDGE CHANNEL IAW SRM 51-24-35-02-01 AND 53-40-21-00-01. PERFORMED ECI ON DOOR SILL IAW TASK CARD 6-53-1013. NO CRACKS NOTED. LOCATED ALL FASTENER HOLES IAW SRM 51-40-05-00-01 AND 51-40-07-02-1. TREATED, PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED CHANNEL IAW TASK CARD 6-53-1013. TOP COATED FASTENERS IAW SRM 51-25-25-02-01. APPLIED LPS HARDCOAT CORROSION INHIBITOR IAW AMM 51-25-01-390-801. ALL WORK DONE IN CONFORMITY WITH TASK CARD 6-53-1013.