What was found
STANTION AT FRAME 236 IS CORRODED BY STRINGER 31P. REMOVED STRINGER TO FRAME ANGLE AND BLENDED AWAY CORROSION PER SR, 51-21-00-00-01. REMAINING THICKNESS IS .014, OUT OF LIMITS. INSTALLED NEW STANTION IAW SRM 51-42-05-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STANTION AT FRAME 236 IS CORRODED BY STRINGER 31P. REMOVED STRINGER TO FRAME ANGLE AND BLENDED AWAY CORROSION PER SR, 51-21-00-00-01. REMAINING THICKNESS IS .014, OUT OF LIMITS. INSTALLED NEW STANTION IAW SRM 51-42-05-01-01.