What was found
LT STUB FRAME FLANGE BELOW THE FORWARD PASSENGER DOOR THRESHOLD AT STATION X6.0 BETWEEN STRINGERS 24P AND 25P HAS CORROSION. OUTSIDE OF LIMITS. FABRICATED AND INSTALLED NEW FLANGE IAW 51-42-05-02-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT STUB FRAME FLANGE BELOW THE FORWARD PASSENGER DOOR THRESHOLD AT STATION X6.0 BETWEEN STRINGERS 24P AND 25P HAS CORROSION. OUTSIDE OF LIMITS. FABRICATED AND INSTALLED NEW FLANGE IAW 51-42-05-02-01.