What was found
LEFT STUB FRAME FLANGE BELOW THE PASSENGER DOOR THRESHOLD AT STA 28.0 BETWEEN STRINGERS 24P AND 25P HAS CORROSION. OUTSIDE OF LIMITS. FABRICATED NEW FLANGE AND INSTALLED IAW SRM 51-42-05-02-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT STUB FRAME FLANGE BELOW THE PASSENGER DOOR THRESHOLD AT STA 28.0 BETWEEN STRINGERS 24P AND 25P HAS CORROSION. OUTSIDE OF LIMITS. FABRICATED NEW FLANGE AND INSTALLED IAW SRM 51-42-05-02-01.