What was found
FRAME FLANGE HAS CORROSION AT STA 71.2 BETWEEN S33-32S. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-2344. FOUND OUT OF LIMITS RD 8/4-53-2344. REMOVED CAP FLANGE IAW RD 8/4-53-017. CONFIRMED CRACK FREE AND FABRICATED ANGLE IAW RD 8/4-53-017. INSTALLED ANGLE IAW SRM 51-42-05-02-01. ALODINED, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-05-02-01. APPLIED MOISTURE DISPLACING COMPOUND IAW AMM 51-25-01-390-801. REPAIR DONE IN COMPLIANCE WITH RD 8/4-53-017.