As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME FLANGES HAVE CORROSION AT STA 116 BETWEEN STR 32-29S. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-2344. REMAINING THICKNESS .042", CONFIRMED CRACK FREE. MATERIAL LOSS WITHIN LIMITS RD 8/4-53-2344. COMPLETED REPAIR IAW RD 8/4-53-2344.