What was found
FRAME FLANGES HAVE CORROSION AT STA 136 BETWEEN STRS 32-29S. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-2344. REMAINING THICKNESS .042", CONFIRMED CRACK FREE. MATERIAL LOSS WITHIN LIMITS OF RD 8/4-53-2344, REPAIRED IAW RD 8/4-53-2344.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME FLANGES HAVE CORROSION AT STA 136 BETWEEN STRS 32-29S. REMOVED RIVETS AND CORROSION IAW RD 8/4-53-2344. REMAINING THICKNESS .042", CONFIRMED CRACK FREE. MATERIAL LOSS WITHIN LIMITS OF RD 8/4-53-2344, REPAIRED IAW RD 8/4-53-2344.