As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME FLANGES HAVE CORROSION AT STA 236 BETWEEN STRS 32-30P. REMOVED RIVETS AND BLENDED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS .041", CONFIRMED CRACK FREE. FLANGES FOUND TO BE WITHIN LIMITS OF RD 8/4-53-2344. REPAIRED IAW RD 8/4-53-2344.