As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SKIN AT FWD FUSELAGE STA X-19.775 BETWEEN STR 27 AND 28, FIRST BAY BELOW LAV SERVICE DOOR FOUND 1 DENT WITH GOUGE. UPON REMOVAL OF PAINT FOUND DENT TO BE FILLED WITH EPOXY, REMOVED EPOXY AND MEASURED DENTED AREA, FOUND DENT TO BE CRACKED REF NTM 51-00-01-250-801, PART 6. THICKNESS REMAINING IN DENT AREA .026" REF NTM 51-00-02-250-801 PART 4. ACFT DOWN FOR C-CHECK.