As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GOUGE IN FUSELAGE AFT OF FRAME AT STA -18.250 BETWEEN STRINGERS 28S AND 29S. SMOOTHED GOUGE IAW 51-14-00-02-03. ACCOMPLISHED THICKNESS GRID OF SMOOTHED AREA, MIN REMAINING THICKNESS .047" REF NTM 51-00-02-250-801. CONFIRMED DAMAGE AREA CRACK FREE REF NTM 51-00-01-250-801.