What was found
CORROSION AND WEAR DAMAGE FOUND IN LAV SERVICE DOOR SURROUND DOUBLER AT STA 1.00. REMOVED CORROSION FROM AREA IAW BOMBARDIER SRM 51-21-00-00-02. ACCOMPLISHED THICKNESS GRID OF AREA, MIN REMAINING THICKNESS .046" REF NTM 51-00-02-250-801 PART 4. CONFIRMED DAMAGED AREA IS CRACK FREE REF NTM 51-00-01-250-801. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-4159. ALODINED PRIMED AND PAINTED IAW RD 8/4-53-4159. COMPLIED WITH RD 8/4-53-4159.