What was found
CORROSION AT FRAME ATTACH FLANGE AT X116 BETWEEN L STR 29 AND L STR 30. BLENDED CORROSION ON FLANGE IAW RD 8/4-53-2344. TREAT, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-10-02-01, AND 51-25-15-02-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AT FRAME ATTACH FLANGE AT X116 BETWEEN L STR 29 AND L STR 30. BLENDED CORROSION ON FLANGE IAW RD 8/4-53-2344. TREAT, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-10-02-01, AND 51-25-15-02-01.