As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME 1.0 FLANGE IS CORRODED STR 29P TO 30P. REMOVED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .046" CONFIRMED AREA CRACK FREE RE NTM 51-00-02-250-801. MATERIAL FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED AND PRIMED FLANGE AND FINISHED REPAIR IAW RD 8/4-53-2344.