As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
REMOVED FWD LOWER EMERGENCY DOOR SILL IAW SRM 51-42-05-02-01. REMOVED SUPPORT BEAM IAW SRM 51-42-05-02-01, SUPPORT BEAM FOUND TO BE CORRODED OUT OF LIMITS IAW SRM 53-20-21-00-01. LOCATED HOLES IN NEW BEAM IAW SRM 51-40-07-02-01. INSTALLED NUTPLATES IAW SRM 51-42-05-02-01. INSTALLED NEW SUPPORT BEAM IAW SRM 51-42-05-02-01 AND 51-42-45-02-01. INSTALLED DOOR SILL IAW SRM 51-41-05-02-01.