What was found
STRINGER 24S SPLICE IS CORRODED BY STA 236. REMOVED CORROSION IAW SRM 51-21-00-00-01. CONFIRMED BLEND AREA CRACK FREE REF NTM 51-00-01-250-801. MEASURED MINIMUM REMAINING THICKNESS .023", FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-4146. ALODINED, PRIMED, PAINTED AND APPLIED CPC IAW RD 8/4-53-4164. COMPLIED WITH TASK CARD RD 8/4-53-4164.