What was found
FRAME 8 SKIN ATTACH ANGLE BELOW PAX DOOR TORQUE TUBE IS CORRODED. REMOVED 2.6" X 1.3" X .005" AREA OF CORROSION FROM FRAME 8 SKIN ATTACH ANGLE BELOW PAX DOOR TORQUE TUBE IAW SRM 51-21-00. ATTACH ANGLE IS OUT OF LIMITS IAW SRM 53-20-23. REMOVED ATTACH ANGLE IAW SRM 51-42-05. FABRICATED NEW ATTACH ANGLE IAW DWG 85329542. INSTALLED NEW ANGLE IAW SRM 51-42-05. APPLIED ALUMINIZED PAINTED IAW SRM 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-05-390-801. COMPLIED WITH TASK CARD 6-53-1057.