What was found
FRAME 94.8 FLANGES ARE CORRODED STR 31P TO 30S. REMOVED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS NOTED .036", CONFIRMED AREA CRACK FREE REF 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. PREPPED, PRIMED, PAINTED AND APPLIED CPC IAW RD 8/4-53-2344.