What was found
FRAME 584.5 FLANGES ARE CORRODED STR 32P TO 31S. REMOVED CORROSION IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS NOTED .042", CONFIRMED AREA CRACK FREE REF 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-2344. CUT AWAY DAMAGE SECTION AND COMPLETED REPAIRS IAW RD 8/4-53-017 AND RD 8/4-53-2344.