What was found
FRAME FLANGE AT STA 100 IS CORRODED STR 24S-23S. ACFT DOWN FOR C-CHECK. REMOVED CORROSION AND 1 RIVET IAW RD 8/4-53-2344. MINIMUM REMAINING THICKNESS .061, CONFIRMED CRACK FREE REF NTM 51-00-02-250-801 AND 51-00-01-250-801. MATERIAL LOSS WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED INSTALLED RIVET IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. APPLIED TOPCOAT AND CPC IAW RD 8/4-53-2344.